Reactor Type:VFX series (High Pressure Vessel)
For endurance test of parts against refrigerant gas etc.

Feature
Heating/cooling test is carried out repeatedly under pressurized atmosphere such as refrigerant gas.
Electric cables to apply voltage can be inserted into pressure vessel.
Specification
| Type | VFX-3070 | VFX-4050 | VFX-5050 |
| Pressure | 7MPa(G) | 5MPa(G) | 5MPa(G) |
| Temperature | 200 degrees C | ||
| Voltage applying terminal | 4 poles 15KV | ||
| Power supply 200V | 1.6kw | 3kw | 4kw |
| Thermocouple | 4pairs | ||
| Outside dimension W*D*H | 800*600*1000mm / 1000*800*1100mm | ||